  • How to deal with the problem of electric heating pipe failure?
  • 9/19/2017 Views: [557]

  • First, the electric heating tube does not generate heat
    Failure analysis: abnormal power supply or power failure; the fuse has blown; poor contact between the power cord plug and the power socket or the power cord wire is disconnected; the blade or lead of the electric heating tube is disconnected to cause a short circuit; the electric heating tube is burned out; the contact of the thermostat is in contact Defective or melting away.
    Treatment method: use after power supply is normal; replace the fuse of the same type; repair or replace; resolder; replace the electric heating tube of the same specification; repair or replace.
    Second, the electric heating tube blows the fuse
    Failure analysis: the fuse diameter is too small and the capacity is insufficient; the power cord plug is shorted to the power outlet; the electric heating tube's insert or lead is disconnected to cause a short circuit; the electrical heating tube (resistance wire) is burned or caused a short circuit; the electrical heating socket is caused by dirt or carbonization Short circuit.

    Treatment method: Replace the appropriate fuse; repair or replace the power plug or socket; reconnect it firmly; repair or replace; clear the dirt, repair or replace the parts.

    Three, the thermostat of the heating pipe fails
    Failure analysis: The thermostat porcelain contact rod is stuck by a foreign body; the hot bimetal is deformed; the moving and static contacts are fatigued and lose elasticity; the moving and static contacts are stuck and cannot be opened and closed; the moving and static contact plate fastening screws are loose Take off.
    Handling method: remove foreign objects, move by hand to move up and down flexibly; adjust the amount of deformation to restore the original shape and elasticity; adjust the angle of the contact to restore elasticity; grind the contact, replace it with a new one if it has no effect; retighten
    Four, electric heating tube leakage
    Fault analysis: Connect the ground wire; the electric heating socket or power plug is too dirty; the circuit wires fall off and touch the cup body; the insulation of the electric heating pipe (heating wire) is damaged; the electric heating pipe (heating wire) is burned out and the cup is shorted; Improper cleaning, divide into junction box.
    Treatment method: Connect the ground wire according to requirements; dry after cleaning; check for broken wires and re-solder; repair or replace; replace the electric heating tube with the same specifications; clean and dry properly.